TABLE MODEL IONIZING AIR BLOWER(HT2611)
It is designed as the theory of alternating current electrostatic eliminator, belongs to electrical category.Apply to eliminate electrostatic in a limited distance, convenient to remove and install.The ionizing air volume can be adjusted, including high voltage generator.
|
Specification: |
|
Operating Voltage |
110V/60HZ OR 220V/50HZ |
|
Current Consumption |
0.25A OR 0.12A |
|
Operating Temperature |
-10~50℃ |
|
Size |
90mm(L)×170mm(W)×260mm(H) |
|
Weight |
3.3Kg |
|
Air Volume |
45~110CFM |
|
Ion Balance |
0V±10V |
|
Air Coverage |
40cm×60cm
|
|
Decay tdst Results: |
|
Testing Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH |
|
Distance |
|
300mm |
600mm |
900mm |
|
Decay time |
Positive |
1.2s |
2.5s |
3.9s |
|
Negative |
1.3s |
2.6s |
4.1s |
|
Offset voltage |
Positive |
8V |
5V |
4V |
|
Negative |
-7V |
-6V |
-3V | |